Quick Measure
Type a few dimensions of a room, wall, foundation, slab, column or beam and get every quantity that follows, as dimension paper.
Not everything needs a drawing on the screen. Quick Measure takes the few dimensions a QS reads off a drawing or a site and writes every quantity that follows from them as rows of the measurement sheets, with the openings deducted, exactly as on dimension paper.
Steps
- 1On a BoQ in Draft or Tender press Quick Measure at the top; on a draft variation order, Quick Measure in its top bar.
- 2Choose the Template, type the Location / name (written on every row, e.g. Office 1, ground floor) and How many identical.
- 3Type the dimensions in metres, and the openings for a room or a wall.
- 4Press Calculate. Each quantity is listed with its unit, how it is Measured as, and the BoQ item HodariQ found for it.
- 5Untick any you do not want; choose or change Add to BoQ item, or leave it empty and choose New item in bill with a New item description.
- 6Press Add to the Measurement Sheets. Back returns to the dimensions.
The templates
| Template | You type | It gives |
|---|---|---|
| Room (floor, ceiling, walls, skirting) | Length, width, height; doors and windows | Floor finish and ceiling L x W; wall plaster / paint 2(L+W) x H less openings; skirting 2(L+W) less door widths |
| Wall (walling and plaster) | Length, height, plastered sides (0, 1 or 2); openings | Walling L x H less openings; plaster times the sides, less the openings on each side |
| Strip foundation | Centre-line length, trench width and depth, blinding and footing thickness, wall thickness and height | Excavation, blinding, concrete in footing, foundation walling, backfilling, disposal of surplus |
| Floor slab | Length, width, thickness | Concrete L x W x T; soffit formwork L x W; edge formwork 2(L+W) x T |
| Columns | Section b and d, height of one | Concrete b x d x H; formwork 2(b+d) x H |
| Beams | Section b and d, length of one | Concrete L x b x d; formwork to sides and soffit L x (b+2d) |
Openings start at 0.9 x 2.1 m for doors and 1.2 x 1.2 m for windows; type the number of each. How many identical multiplies every row.
The foundation
The excavation is the whole trench. What stays in the trench (blinding, footing and the walling below ground, up to the trench depth) is deducted from the backfilling and is the disposal, so backfilling plus disposal always equals the excavation.
Where the rows go
- The BoQ item for each quantity is found by its unit and its key words, all of which must be in the item's description (floor; ceiling; plaster; skirting; concrete and slab; backfill...). Check every one.
- The rows are added after the item's own rows; an item that had a quantity typed and no rows keeps it as Quantity before measuring.
- With no item chosen, a new item is made in the bill shown; in a variation order, a new addition at a new rate, to price.
- The blinding and footing together cannot be deeper than the trench: HodariQ says so.
Good to know
Quick Measure writes rows once: it keeps no link to the dimensions typed. To change them, edit the rows on the measurement sheet, or delete them and measure again. For a link that follows changes, measure on the drawing. Quick Measure is in the Professional and Enterprise plans.
Something unclear? Ask us on WhatsApp: we answer the same day.